SP-910 | Fluorometer, Colorimeter, & Turbidimeter

Simple. Robust. Intelligent.


PTSA and fluorescein

  • Measure PTSA and fluorescein in the same meter for your traced programs in cooling and boiler applications.

Calibrate ST-500 Directly

  • Calibrate a nearby ST-500 via built-in Bluetooth after measuring sample concentration. No laptop or other tool is needed.

User-defined Programs

  • User-defined programs are supported with non-linear calibration curves. Choose from over 60 programs, including reagent-less nitrite and chlorine dioxide measurement.

Battery Life Doubled

  • Battery life is six months or more, even with higher resolution LCD readable in direct sunlight.

More Upgrades

  • Turbidity range is extended to 0-100 and 0-1000 NTU with auto-ranging. 16mm tube adapter is available for programs that require digestion. The SP-910 talks to your smart phone for firmware upgrades and data log transfer.

PTSA Determination with Immunity to Color and Turbidity Interference

Maximum rejection to sample color and turbidity interference by state-of-the-art optical design and proprietary compensation algorithm.

PARAMETERDESCRIPTION,CORRESPONDING HACH® PRMP NUMBERRANGE (PPM)NO₂Direct nitrate,no reagent needed,Pyxis method1001000ClTurbidimetric method for chloride ion,Low Range,Pyxis method440ClTurbidimetric method for chloride ion,Middle Range,Pyxis method40400Mg2+Magnesium,EBT method,Middle Range,Pyxis method10100Mg2+Magnesium,EBT method,High Range,Pyxis method100400PolymerTurbidimetric method for anionic polymers,Pyxis method0.213.0ClO₂Direct reading automatic range selection,Pyxis method0.23000BleachDirect Method measuring sodium hypochlorite concentration,Pyxis method1%12%ChlorineChlorine,Free,DPD,PRMP 90.022.2ChlorineChlorine,Total,DPD,PRMP 90.022.2ChlorineHigh Range DPD Chlorine,No sample change needed.PRMP 120.16.0CuCopper,Bicinchoninate Method,PRMP 200.025.0CuPorphyrin Method for Copper,PRMP 220.0060.2DEHADEHA,Iron Reduction Method for Oxygen Scavengers,PRMP 250.0090.5Ca2+Calcium:Calmagite Colorimetric Method,PRMP 290.084.0Mg2+Magnesium:Calmagite Colorimetric Method,PRMP 300.134.0FeIron,1,10 phenanthroline Method,PRMP 330.033.0FeIron,FreeoZine Method,PRMP 370.0111.3FeIron,TPTZ Method,PRMP 390.041.8FeIron,for cooling water with molybdenum-based treatment,PRMP 380.031.8MoO42-Molybdenum,High Range,Mercaptoacetic Acid Method,PRMP 440.240.0MoO42-Molybdenum,Low Range,Ternary Complex,PRMP 470.073.0NO2Nitrite,High Range,Ferrous Sulfate,PRMP 592.0150.0NO2Nitrite,Low Range,Diazotization,PRMP 600.0050.3OPO4Phosphorus,Reactive,Molybdovanadate,PRMP 770.245.0OPO4Phosphorus,Reactive,Orthophosphate Ascorbic Acid,PRMP 790.052.5OPO4Phosphorus,Reactive,Amino Acid,PRMP 850.230.0PhosphonatePhosphonates,Persulfate UV Oxidation,PRMP 800.052.5ClO2Chlorine Dioxid,DPD,PRMP 1120.045.0ClO2Chlorine Dioxid,Direct Reading,PRMP 77.350.0SiO2Silica,High Range,Silicomolybdate,PRMP 891.075.0SiO2Silica,Low Range,Heteropoly Blue,PRMP 900.021.6AzoleBenzotriazole,UV Photolysis Method,PRMP 30.716.0SO42-Turbidimetric method for Sulfate.PRMP 914.970.0Cr(VI)Hexavalent chromium,1,5-Diphenylcarbohydrzaide Method,PRMP 130.010.6CrChromium total Alkaline Hypobromite Oxidation Method, PRMP 150.010.6NH3-NSalicylate Method, PRMP 640.020.5Mn2+Low Range Manganese PAN Method, PRMP 430.020.7Mn2+High Range Manganese,Periodate Oxidation Method, PRMP 410.220.0NH2ClIndophenol Method for MonoChloramine,PRMP 1100.13.0AlAluminon Method for Aluminum,PRMP 10.020.8FSPANDS 2 Method for Fluoride,PRMP 270.052.0ZnZincon Method for Zinc,PRMP 970.023.0S2-Methylene BlueMethod for Sulfide,PRMP 930.010.7CNPyridine-Pyrazalone Method for Cyanide,PRMP 230.0080.2N2H4P-Dimethylaminobenzaldehyde Method for Hydrazine, PRMP 310.0160.5NO3-NMiddle range nitrate, PRMP 540.25.0NO3-NHigh range nitrate, PRMP 510.830.0NiPAN Method for Nickel,PRMP 480.0131.0(HOCN)3Turbidimetric Method,PRMP 2475pHPhenol red method pH, PRMP 756.58.5

SP-910 Specifications

Range0-300 ppb PTSA, 0-1,000.0 ppb fluoresceinColorimeter Wavelength420,455,525,560,570 and 610 nmTurbidity Excitation WavelengthWhite and IR LEDFluorescence Excitation Wavelength365/470 nm LEDFluorescence Emission Wavelength410/525 nm LEDWavelength Accuracy±1 nmAbsorbance Reproducibility0.005 au in the range of 0 to 1.0 au (3 sigma)Absorbance Linearity range0 to 1.0 auFluorescence Reproducibility0.3 ppb PTSA/0.03 ppb fluorescein (3 sigma)Fluorescence Detection Limit1 ppb PTSA/0.1 ppb fluoresceinTurbidity Range0-100/0-500 NTU Auto RangeTurbidity Detection Limit1 NTUBattery4 AA alkalineTypical Battery Life6 monthsDisplayLCD display, visible under direct sunlightDimensions (L x W x H)265 x 88 x 69 (mm)Weight600g (without battery)Temperature Range40 to 106℉(4 to 41℃)Humidity85% at 106℉(41℃)EnvionmentalIP67, dustproof and waterproof

*Note: Specifications are subject to change without notice.Contact Pyxis product support (support@pyxis-lab.com) for updates.